Technical Information / Datasheet
Connection unit SK TI4-TU-BUS-C
1.0 Erstausgabe / first issue 1613 Rck TI 275280500 GB
version reason for change(s) issue name document speech
Pos: 2 /T echnis che Inf orma tion en/SK xU x - Bus - Er weit erung en/ A nsc hluss ei nheit [S K TI 4-TU-.. .]/SK T I4-TU4- BUS-C / 27 528 050 0 / Basi si nfor mati on en [ SK T I4-TU- BUS-C ] @ 3 \mod_1364468636695_388.docx @ 62945 @ 555 @ 1
SK TI4-TU-BUS-C
Part number: 275 280 500
Bus connection unit
ATTENTION
Validity of document
This document is only valid in combination with the operating instructions for the relevant frequency converter. All
of the information that is relevant for a safe start-up of this assembly and the frequency converter is only available
under these conditions
Scope of delivery
1 x Bus connection unit SK TI4-TU-BUS-C
1 x System bus cable set grey / black
1 x 24 VDC cable set brown / blue
1 x PE cable green/yellow
1 x Gasket 2 mm, self-adhesive
2 x Leadthrough grommet 22 mm x 9.5 mm
4 x Hexagon socket M4 x 20
1 x Diaphragm valve M12x1.5 RAL9005
1 x Reducer (brass) M20 à M12
Usage area
The bus connection unit forms the basis for the bus options and IO - expansions of model SK TU4-.
The terminal strip is divided into three potential levels. The functions of the individual terminals are
dependent upon the selected field bus or IO - expansion and are not defined until both elements are
joined together (BUS - connection unit and field bus or IO expansion). The BUS - connection unit can
be fitted to or in the immediate vicinity of a frequency converter (SK 180E … SK 2xxE).
Technical data
Temperature range -25 °C … 50 °C Vibration resistance 3M7
Temperature class Class 3k4 Hardware version BB
Protection class IP66 Dimensions [mm] H x W x D: 95 x 136 x 55
Current rating 3A
Pos: 3 /T echnis che Inf orma tion en/SK xU x - Bus - E rwei ter ung en/ Ans chl uss einh eit [SK TI4- TU-...]/M er kmale [SK TI 4-TU-BU S] @ 3\mod_1364469965939_388.docx @ 62995 @ 5 @ 1
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - SK TI4-TU-BUS-C

Technical Information / Datasheet Connection unit SK TI4-TU-BUS-C 1.0 Erstausgabe / first issue 1613 Rck TI 275280500 GB version reason f

Pagina 2 - ATTENTION

Connection unit – SK TI4-TU-BUS-C 2 TI 275280500 - 1613 Features 1. No function, M20 x 1,5 2. Diagnosis access, RJ12 socket 3. Cable entry

Pagina 3

Connection unit – SK TI4-TU-BUS-C TI 275280500 - 1613 3 The installation steps described in the following are valid for attaching a connection u

Pagina 4

Connection unit – SK TI4-TU-BUS-C 4 TI 275280500 - 1613 Information Contacting The connection between the field bus or IO - expansion and the